You have reached this page because of your interest in the Power Supply NSN parts we have available on NSN Domain. Here, you can submit a quote request for Ametek Programmable Power Inc part number 500-2, a component that can be located by searching for NSN 6130-01-363-0912 in our database. Apart from part number 500-2, we also have an array of others, including military, defense, and aerospace parts that have been sourced from a wide range of trusted manufacturers on our Approved Vendor List (AVL). With this in mind, we invite you to explore our ever-expanding catalogs for in-demand items according to manufacturer, NSN, NIIN, and more.
Note : We Will Not Share Your Information To Any Third Parties.
NSN Domain works with numerous government and defense agencies, so we take advantage of CAGE Codes like 25965 to uniquely identify items in a standardized manner. Moreover, we organize our stock according to various Federal Supply Classes (FSC), ensuring customers can find Ametek Programmable Power Inc part number 500-2, which can be found under the FSC 6130 Converters Electrical Non Rotating with ease. On that note, please complete the form below for NSN 6130-01-363-0912 and/or any others so we can see how we can find a solution to your needs. For a hands-on approach, call or email us at any time; our experts are on standby 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-363-0912 Item PartTypeName: POWER SUPPLY | 6130 | 013630912 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
500-2 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
APNX | INPUT VOLTAGE RATING | 115.0 AC POUNDS PER HOUR WET 1ST ALTERNATE OPERATING POWER RQMT |
APTS | OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM 3RD POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM 1ST POWER OUTPUT AND 9.2 AC AMPERES MAXIMUM 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM 2ND POWER OUTPUT AND 2.25 AC AMPERES MAXIMUM 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM 3RD POWER OUTPUT AND 1.1 AC AMPERES MAXIMUM 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 1500.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 2ND ALTERNATE OPERATING POWER RQMT |
ABKW | OVERALL HEIGHT | 5.250 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APPA | OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM 2ND POWER OUTPUT AND 130.0 AC VOLTS MAXIMUM 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM 3RD POWER OUTPUT AND 260.0 AC VOLTS MAXIMUM 3RD POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 2ND POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 1ST ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 2ND ALTERNATE OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM 1ST POWER OUTPUT AND 32.0 AC VOLTS MAXIMUM 1ST POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
APTS | OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM 1ST POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 1ST POWER OUTPUT |
CBBL | FEATURES PROVIDED | PROGRAMMABLE AND OVER TEMPERATURE PROTECTION AND OVER VOLTAGE PROTECTOR |
CWGN | OUTPUT PHASE | TWO 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHT | INPUT CONNECTION QUANTITY | 1 1ST ALTERNATE OPERATING POWER RQMT |
ABHP | OVERALL LENGTH | 19.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 16.000 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | F110 ACFT/GE100 ENG |
ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR WET 2ND ALTERNATE OPERATING POWER RQMT |
APTS | OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM 2ND POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 2ND POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/50.0 DEG CELSIUS |
CWGN | OUTPUT PHASE | TWO 1ST POWER OUTPUT |
CWGN | OUTPUT PHASE | TWO 3RD POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 3RD POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 1500.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
FEAT | SPECIAL FEATURES | CONSIST OF:2 EA MODEL 251B;1 EA 400SR AND 1 EA 990-302-92 CABLE PLUS ASELECTED OSCILLATOR |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote